Quick links(Products)

Rack-IOT(42-U)
In the ever-evolving World of technology, Optmystic is at the forefront,of top-notch solutions for businesses using IOT-AI-ML
ENTERPRISE LEVEL IoT CONTROLLER MASTER AND SLAVE : with capability to c o n t r o l 1 0 0 0 + p a r a m e t e r s communication modes are LORA, Wi-Fi, GSM based best fit for TELCOs, railways, metro, airports, roadways, hospitals, hospitality, manufacturing, cold storages, blood banks, banking sector, builders etc.
Rack Type
"ACOUTDOOR"
Color
"Ash White"
Rack Height(mm)
"2020"
Rack Depth(mm)
"800"
Rack Width(mm)
"1075"
Wheels(mm)
"101.6"
Wheels(numbers)
"6"
Main Lock
"Biometric"
"access card"
"Biometric"
AC Door Lock
"electrical"
Side Door Lock
"electrical"
Back Door Lock
"electrical"
PDU Inbuilt
"32AMP MSB, 6X5/15AMP"
Temperature
"Temperature Monitoring & Management of AC Switching "
Humidity
"Humidity Monitoring & Management "
AQI
"Air Quality Index Monitoring"
So2
"Sulfer Di Oxide Monitoring"
Co2 & Co
"Carbon Di Oxide & Carbon Monooxide Monitoring"
Inteligent Rack Management
"Personalized Dashboard to Manage and Monitor & Health Management of AC and other equipments"
4G
"4G/5G Data Sim for Cloud Communication "
Wi-Fi
"Wi-Fi Module for Cloud Connectivity & Communication "
Topology
"Hub and Spoke/ Fully Mesh/Partial Mesh"
Logging
"On Appliance Log and Report/Centralized Logging/SysLog Support/Graphical real-time Logging & monitoring"
Security
"Built-in Security features such as Encryption & Firewalls"
Cost
"Reduce the costs associated with the traditional WAN solution/Leased lines"
Network Function Virtualization
"Enables the deployment of the deployment of network service as a software based virtual appliance"
Network Performance
"It uses intelligent routing and optimization techniques for network traffic management/Improves Performance & application experience"
Intrusion Previntion System
"IDS + Next generation IPS/ Custom signature/ P2P applications signatures/ Automatic Signature updates/ Allow & Drop Packet"
Rated AC output and UPS Power (W)
"3600"
Peak Power(Off Grid)
"2 Times of rated Power, 10s"
Max DC Input Power (W)
"4680"
Output frequency & Voltage
"50/60Hz; 220/230 Vac (Single Phase)"
Startup Voltage (V)
"125"
Efficiency
"Max. Eff. :- 97.6%"
Operating Temp. Range
":-25~60 °C, > 45°C Derating"
Protection Degree
"IP65"
Total Energy (KWh)
"9.6"
Operating Voltage
"39~54.75"
LED Indecators
"Yes"
Reset Button
"Yes"
Display Screen
"Yes"
Charging Curve
"3 Stages/Equalization"
Charging strategy for Li-Ion Battery
"Self Adaption to BMS"
PV Input Lightning
"Integrated"
Anti-Islanding
"Integrated"
Insulation Resistor Detection
"Integrated"
Residual Current Monitoring
"Integrated"
Output Over Current
"Integrated"
Output Shorted Protection
"Integrated"
Output Over Voltage Protection
"Integrated"
Surge Protection
"DC Type II/ AC Type II"